E I DUPONT DE NEMOURS & CO INC -- FREON 13B1 REFRIGERANT -- 6830-01-310-3406
=====================  Product Identification  =====================

Product ID:FREON 13B1 REFRIGERANT
MSDS Date:05/01/1989
FSC:6830
NIIN:01-310-3406
=== Responsible Party ===
Company Name:E I DUPONT DE NEMOURS & CO INC
Address:1251 BRANDYWINE BLDG
City:WILMINGTON
State:DE
ZIP:19898
Country:US
Info Phone Num:800-441-9450;302-999-5072
Emergency Phone Num:800-441-3637;800-424-9300(CHEMTREC)
Preparer's Name:K.P. BROWN
CAGE:0ERJ7
=== Contractor Identification ===
Company Name:DU PONT E I  DE NEMOURS AND CO INC   PETROCHEMICALS DEPT
Address:1251 BRANDYWINE BLDG
Box:City:WILMINGTON
State:DE
ZIP:19898
Phone:302-773-5676
CAGE:73925
Company Name:E I DUPONT DE NEMOURS & CO, INC.
Address:1007 MARKET STREET
City:WILMINGTON
State:DE
ZIP:19898
Country:US
Phone:800-441-7515
CAGE:0ERJ7

=============  Composition/Information on Ingredients  =============

Ingred Name:METHANE, BBROMOTRIFLUORO-;
CAS:75-63-8
RTECS #:PA5425000
Fraction by Wt: 100%
OSHA PEL:1000 PPM (MFR)
ACGIH TLV:1000 PPM (MFR)
Ozone Depleting Chemical:1

Ingred Name:SUPP DATA:CAUSE TEMP ALTERATION OF THE HEART'S ELEC
    ACTIVITY W/IRREG PULSE, PALPITATIONS, OR INADEQ CIRCULATION. (ING
    3)
RTECS #:9999999ZZ

Ingred Name:ING 2:SKIN/EYE CONT W/LIQ MAY CAUSE FROSTBITE. INDIVIDUALS
    W/PREXISTING DISEASES OF CENTRAL NERV/CARDIOVASCULAR (ING 4)
RTECS #:9999999ZZ

Ingred Name:ING 3:SYS MAY HAVE INCREASED SUSCEPTIBILITY TO TOXICITY OF
    EXCESSIVE EXPOSURES.
RTECS #:9999999ZZ

Ingred Name:FIRST AID PROC: EPINEPHRINE, SHOULD BE CONSIDERED ONLY AS
    LAST RESORT IN LIFE-THREATENING EMERGENCIES.
RTECS #:9999999ZZ

Ingred Name:VENT: USED IN LOW PLACES.
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:INHAL OF HIGH CONC OF VAP IS HARMFUL &
    MAY CAUSE HEART IRREG, UNCON, OR DEATH. INTENTIONAL MISUSE CAN BE
    FATAL. VAP REDUCES O*2 AVAIL FOR BRTHG & IS HVR/AIR. LIQ CONT CAN
    CAUSE FROSTBITE. EFTS SEEN IN  ANIMALS FROM EXPOS BY INHAL RANGE
    FROM"NO OBSERVED ADVERSE EFTS" @ LOW TO MOD CONC TO CNS SYS EFTS
    (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:@ HIGH (4%) CONC. PNEUM, LIVER, &
    KIDNEY EFTS WERE SEEN IN ANIMALS EXPOS BY INHAL TO LETHAL/NEAR
    LETHAL CONC. CARDIAC SENSIT WAS OBSERVED IN DOGS EXPOS TO CONC OF
    7.5% HIGHER. ANIMAL TEST IND ICATES THAT THIS CMPD DOES NOT HAVE
    MUTAGENIC OR EMBRYOTOX EFTS. NO ANIMAL TEST RPTS ARE AVAIL TO
    DEFINE (SUPP DATA)
Medical Cond Aggravated by Exposure:INDIVIDUALS WITH PRE-EXISTING
    DISEASES OF THE CNS OR CARDOIVASCULAR SYSTEM MAY HAVE INCREASED
    SUSCEPTIBILITY TO THE TOXICITY OF EXCESSIVE EXPOSURES.

=======================  First Aid Measures  =======================

First Aid:INHAL:IMMED REMOVE TO FRESH AIR. KEEP PERSONS CALM. IF NOT
    BRTHG, GIVE ARTF RESP, IF BRTHG IS DFCLT, GIVE O*2. CALL PHYS.
    SKIN:FLUSH W/H*2O. TREAT FOR FROSTBITE IF NEC. EYE:IMMED FLUSH
    W/PLENTY OF H*2 O FOR @ LST 15 MIN. CALL PHYS. INGEST:INGEST IS NOT
    CONSIDERED A POTNTL RTE OF EXPOS. CALL MD . NOTE TO PHYS:BECAUSE OF
    POSS DISTURB OF CARDIAC RHYTHM, CATECHOLAMINE DRUGS, SUCH AS (ING
    5)

=====================  Fire Fighting Measures  =====================

Flash Point:WILL NOT BURN
Extinguishing Media:AS APPROPRIATE FOR COMBUSTIBLES IN AREA.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
    PROTECTIVE EQUIPMENT . USE WATER SPRAY OR FOG TO COOL CONTAINERS.
Unusual Fire/Explosion Hazard:CYLINDERS ARE EQUIPPED WITH TEMPERATURE
    AND PRESSURE RELIEF DEVICES BUT MAY STILL RUPTURE UNDER FIRE
    CONDITIONS. DECOMPOSITION MAY OCCUR.

==================  Accidental Release Measures  ==================

Spill Release Procedures:VENTILATE AREA-ESPECIALLY LOW PLACES WHERE
    HEAVY VAPORS MIGHT COLLECT. REMOVE OPEN FLAMES. USE NIOSH/MSHA
    APPROVED SCBA FOR LARGE LEAK OR SPILL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:CLEAN/DRY AREA. DO NOT HEAT ABOVE
    125F. AVOID BRTHG VERY HIGH CONC OF VAP. AVOID CONT OF EYES/SKIN
    W/LIQUID.
Other Precautions:USE WITH SUFFICIENT VENTILATION TO KEEP EMPLOYEE
    EXPOSURE BELOW RECOMMENDED LIMITS.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:UNDER NORMAL MANUFACTURING CONDITIONS NO
    RESPIRATORY PROTECTION IS REQUIRED WHEN USING THIS PRODUCT.
    NIOSH/MSHA APPROVED SCBA IS REQUIRED IF SPILL OCCURS.
Ventilation:NORM VENT FOR STD MFG PROC IS GENERALLY ADEQ. LOC EXHAUST
    SHOULD BE USED WHEN LG AMT ARE REL. MECH VENT SHOULD BE(ING 6)
Protective Gloves:LINED BUTYL GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
VP: 235PSIA @25C. HAZ DECOMP:POSSIBLY CARBONYL HALIDES. EFTS OF
    OVEREXP: CARCINOGENIC/REPROD HAZ. HUMAN HLTH EFTS OF OVEREXP BY
    INHAL MAY INCL: NONSPEC DISCOMFORT, SUCH AS NAUS, HDCH, OR WEAK; OR
    TEMP  CNS DEPRESS W/EFTS SUCH AS DIZZ/HDCH/CONFUSN, INCOORD, & LOSS
    OF CONSCIOUSNESS. HIGER EXPOS (>13%) BY INHAL MAY (ING 2)

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:-72F,-58C
Vapor Pres:SUPP DATA
Vapor Density:5.14@25C
pH:NEUT
Evaporation Rate & Reference:>1(CCL*4=1)
Solubility in Water:0.03 WT%@25C
Appearance and Odor:CLEAR, LIQUIFIED GAS, COLORLESS, SLIGHT ETHEREAL
    ODOR.
Percent Volatiles by Volume:100

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
ALKALI OR ALKALINE EARTH METALS-POWDERED AL, ZN, BE, ETC.
Stability Condition to Avoid:AVOID EXTENDED CONTACT WITH OPEN FLAMES OR
    TEMPERATURES >1000F.
Hazardous Decomposition Products:FREON 13B1 REFRIGERANT MAY BE DECOMP
    BY HIGH TEMP (OPEN FLAMES, GLOWING METAL SURF, ETC) FORM FREE
    BROMINE & (SUPP DATA)

====================  Disposal Considerations  ====================

Waste Disposal Methods:COMPLY WITH ALL FEDERAL, STATE, AND LOCAL
    REGULATIONS. RECLAIM BY DISTILLATION OR REMOVE TO PERMITTED WASTE
    DISPOSAL FACILITY.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.