PERMABOND INTERNATIONAL -- 78-4310 PERMA-LOK MM 115 -- 8030-01-014-5869
=====================  Product Identification  =====================

Product ID:78-4310 PERMA-LOK MM 115
MSDS Date:03/25/1993
FSC:8030
NIIN:01-014-5869
=== Responsible Party ===
Company Name:PERMABOND INTERNATIONAL
Address:480 SOUTH DEAN STREET
City:ENGLEWOOD
State:NJ
ZIP:07631
Country:US
Info Phone Num:908-685-5000
Emergency Phone Num:908-685-5000
Preparer's Name:PHILIP A. TOSCANO
CAGE:DO525
=== Contractor Identification ===
Company Name:NATIONAL STARCH AND CHEMICAL CORP
Address:10 FINDERNE AVE
Box:6500
City:BRIDGEWATER
State:NJ
ZIP:08807
Country:US
Phone:908-685-5379; FAX:908685-5306
CAGE:85091
Company Name:PERMABOND INTERNATIONAL
Address:480 S. DEAN ST.
City:ENGLEWOOD
State:NJ
ZIP:07631
Phone:201-685-5000
CAGE:DO525

=============  Composition/Information on Ingredients  =============

Ingred Name:TETRAETHYLENE GLYCOL DIMETHACRYLATE
CAS:109-17-1
RTECS #:OZ4000000
Fraction by Wt: >1%

Ingred Name:HYDROXYETHYL METHACRYLATE, ETHYLENE GLYCOL METHACRYLATE
CAS:868-77-9
RTECS #:OZ4725000
Fraction by Wt: >1%
Other REC Limits:3 PPM

Ingred Name:CUMENE HYDROPEROXIDE
CAS:80-15-9
RTECS #:MX2450000
Fraction by Wt: >1%
EPA Rpt Qty:10 LBS
DOT Rpt Qty:10 LBS

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:ORAL LD50 (RAT): 800 MG/KG  (SEE SUPP)
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:EYES: IRRITATION. SKIN: IRRITATION &
    DERMATITIS, SENSITIZATION, PARTIAL OR WHOLE-BODY DERMATITIC RASH.
    INHALATION: RESPIRATORY IRRITATION. INGESTION: NAUSEA & VOMITING.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:SKIN: ABSORPTION MAY PRODUCE NERVOUS SYSTEM
    EFFECTS SUCH AS ATAXIA.

=======================  First Aid Measures  =======================

First Aid:EYES: FLUSH W/PLENTY OF WATER FOR AT LEAST 15 MINS. SKIN:
    WASH W/SOAP & WATER. INHALATION: REMOVE TO FRESH AIR. IF BREATHING
    IS DIFFICULT, GIVE OXYGEN. IF BREATHING STOPS, GIVE ARTIFICIAL
    RESPIRATION.  INGESTION: DON'T INDUCE VOMITING. IF CONSCIOUS, GIVE
    MILK OR WATER TO DILUTE STOMACH CONTENTS. KEEP WARM & QUIET. DON'T
    GIVE ANYTHING BY MOUTH IF UNCONSCIOUS. OBTAIN MEDICAL ATTENTION IN
    ALL CASES.

=====================  Fire Fighting Measures  =====================

Flash Point Method:SCC
Flash Point:230F
Extinguishing Media:CO2, DRY CHEMICAL, FOAM, WATER FOG
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS. COOL
    EXPOSED EQUIPMENT W/WATER SPRAY.
Unusual Fire/Explosion Hazard:POLYMERIZATION MAY TAKE PLACE AT ELEVATED
    TEMPERATURES.

==================  Accidental Release Measures  ==================

Spill Release Procedures:WEAR PROTECTIVE CLOTHING. STOP LEAK IF SAFE TO
    DO SO. TAKE UP SAND OR INERT ABSORBENT MATERIAL & PLACE IN
    CONTAINER FOR LATER DISPOSAL. IN BULK QUANTITIES, PRODUCT ABSORBED
    ON INERT MATERIAL MAY POLYM ERIZE GENERATING SIGNIFICANT HEAT &
    PRESSURE.

======================	Handling and Storage  ======================

Handling and Storage Precautions:AVOID EXCESSIVE HEAT. STORE OUT OF
    DIRECT SUNLIGHT IN A DRY AREA. MAXIMUM STORAGE TEMPERATURE IS 100F.
Other Precautions:KEEP OUT OF REACH OF CHILDREN.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:USE NIOSH APPROVED RESPIRATOR IF VAPOR OR MIST
    LEVELS ARE IRRITATING OR ABOVE TLV LEVELS.
Ventilation:GENERAL
Protective Gloves:RECOMMENDED
Eye Protection:SAFETY GLASSES, GOGGLES OR FACE SHIELD
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE
    REUSE. WASH HANDS BEFORE EATING/DRINKING/SMOKING/USING TOILET
    FACILITIES.
Supplemental Safety and Health
BOILING POINT: POLYMERIZES BEFORE BP ATTAINED. LD50 INFORMATION IS FOR
    CUMENE HYDROPEROXIDE.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:SEE SUPP
Vapor Pres:0.01
Vapor Density:1.01
Spec Gravity:1.070
Solubility in Water:INSOLUBLE
Appearance and Odor:BLUE LIQUID W/MILD, PLEASANT ODOR
Percent Volatiles by Volume:<1

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
METALS & THEIR SALTS; PERMA-LOK ANAROBIC SURFACE CONDITIONERS.
Stability Condition to Avoid:SUNLIGHT, EXCESSIVE HEAT, CONTAMINATION BY
    METALS OR ANAEROBIC SURFACE CONDITIONER
Hazardous Decomposition Products:CO, CO2, & UNIDENTIFIED ORGANIC
    COMPOUNDS
Conditions to Avoid Polymerization:ELEVATED TEMPERATURES

====================  Disposal Considerations  ====================

Waste Disposal Methods:VENT DISPOSAL CONTAINER TO PREVENT BUILDUP OF
    PRESSURE. CAN CAREFULLY SOLIDIFY W/ANAEROBIC SURFACE CONDITIONER &
    DISPOSE OF AS SOLID WASTE. DISPOSE OF IN ACCORDANCE W/FEDERAL,
    STATE & LOCAL REGULATION S.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.